+86(755) 27944155 sales@knownpcb.com
Shenzhen KnownPCB Technology Co., Ltd.

Blog & Design Guide

Blog & Design Guide
Home Blog & Design Guide

PCB Insertion Loss: Dielectric and Conductor Loss

PCB insertion loss describes how much signal is lost between two defined ports at a given frequency. On a uniform PCB trace, much of the attenuation comes from the dielectric and the conductors. A measurement across a longer path also includes whatever launches, vias, connectors and impedance changes lie between the measurement planes. That distinction tells you whether a material change will address the loss you are seeing.

On this page · Read the measurement · Separate the loss mechanisms · Compare stackups · Specify the evidence

Start with frequency and measurement planes

A forward transmission plot usually shows S21 for a single-ended path or Sdd21 for a differential path. A reading of −4 dB on a transmission plot corresponds to 4 dB of insertion loss when loss is reported as a positive magnitude. State the convention and frequency whenever you quote a value. Mark the planes where the measurement starts and ends, and say which test fixture sections were removed by de-embedding. Texas Instruments explains the distinction between transmitted and reflected signals in its S-parameter definitions.

On a uniform line, attenuation accumulates with length. On a path with mismatches, reflections can introduce ripple or a notch. If one board shows a narrow dip and the other shows a steady increase in loss, inspect the launch and via structures as well as the laminate. A good impedance result from a coupon answers a different question from a transmission measurement across the assembled path.

PCB impedance test instrument with a trace on its display

PCB impedance test instrument.

Separate dielectric and conductor loss

Dielectric loss
Some of the field energy is dissipated in the insulating material around the trace. The dissipation factor, Df, is an input to that term. Its measurement frequency and method matter, along with how much of the field is in each material. For example, an outer microstrip and an inner stripline can use the same laminate family and still have different field distributions.
Conductor loss
Current dissipates energy in both the trace and the return conductor. At higher frequencies it concentrates near the conductor surfaces. Finished trace geometry, copper profile and the distribution of return current affect the loss. Ask which copper surface faces the dielectric and which foil or treatment the build will use.

A lower Df reduces the dielectric contribution when the other inputs stay comparable. It does not set the conductor contribution. TI's one-inch trace-loss comparison in section 9 reports loss at 8 and 16 GHz alongside Dk and Df. Read its dB figures as results for the stated trace comparison. The Df numbers alone do not yield the reported trace loss. For copper profile and surface-current background, see copper roughness and skin depth.

Close view of metal carriers on a PCB pattern-plating line

Panel carriers on the pattern-plating line.

Compare like routes before changing materials

At one frequency, imagine two otherwise identical and well-matched transmission lines that are 25 mm and 75 mm long. If their measured losses are 1.3 dB and 2.9 dB with comparable launches, the 50 mm difference is 1.6 dB. That gives an estimated line loss of 0.032 dB/mm at that frequency. This is a worked example. With real coupons, repeat the comparison across the specified band and review whether identical launch loss and sufficiently small reflections are reasonable assumptions.

The length comparison estimates combined line attenuation. To separate material and copper effects, compare controlled builds or use a model with independently specified dielectric and conductor parameters. Change one input at a time in the model and look at the change across the band. A single measured loss value cannot identify how much came from Df and how much came from roughness.

If the longer coupon has an extra via or a different launch, subtracting the measurements also subtracts unequal transitions. Make both coupons on the same layer with the same reference geometry and compare the plots at the same frequencies. Inspect return loss alongside forward transmission. If strong reflections make the curves ripple, use a suitable fixture model or extraction method before treating the length difference as a material result.

Pale high-frequency PCB with exposed copper features

High-frequency PCB with exposed copper features.

Put the frequency band and build on the same request

Send the target loss and frequency band with the routed length, trace layer, reference planes, impedance target, pressed dielectric thickness, laminate construction and foil option. Include the launch structures if the target covers them. For requested measurements, specify the coupon geometry, port configuration, reference planes and reporting format. Ask who will run the measurement and how any fixture contribution will be handled.

If a supplier returns only an impedance report, check the coupon layer and the line geometry it represents. Then ask separately for the transmission evidence your loss budget requires. For differential paths, agree on port pairing and polarity before comparing mixed-mode results. A dramatic change in the trace can come from the way the ports were paired or calibrated, so report those details with the plot instead of copying a screenshot alone.

When purchasing proposes a material substitute, compare the whole construction against the original release. Include finished copper dimensions, the copper profile and material data at a relevant frequency. If the evidence is still missing, keep the substitution open for engineering review. Use the high-frequency and high-speed PCB manufacturing page to start the construction discussion.

PCB Design and Manufacturing Guides

Explore PCB design, materials, fabrication and assembly guides. Use engineering articles to prepare project files and manufacturing requirements.

Discuss a PCB or PCBA manufacturing project

You can submit files via our Message Box for a DFM check and pricing.

Proven by 7 industries, 4000+ customer projects

PCB Insertion Loss: Dielectric and Conductor Loss

Please contact us at sales@knownpcb.com, ask for engineering support here or use the form below to reach out to KnownPCB

Request a Manufacturing Quote

Include your quantity, target delivery date and key requirements. File handling and NDA information.

Support At:
Upload Gerber/PCB File:
Send Message
Name*
Email*
Company Name*
Address
Job Title
Phone Number