Rigid-flex PCB fabrication joins a flexible circuit to rigid sections in one board. The fabrication drawing needs to show which copper layers continue through the flex, where rigid materials stop and which flex surfaces remain exposed. Those decisions guide coverlay preparation, lamination, drilling and removal of the material that temporarily supports or covers the flexible span.
On this page · Define the build regions · Prepare the flex and coverlay · Follow the fabrication sequence · Check before release
Give each rigid section and flex span a name on the same board outline. In the stackup, show the copper and dielectric layers present in each region. A layer that appears on the overall drawing may end at a rigid boundary, while a flex conductor continues under the rigid section. Altium's rigid-flex documentation guidance shows how a region map can identify the different stacks and the areas that need coverlay or a rigid-material opening.
Give the data a common datum and revision. The board outline, rigid window and coverlay opening must line up in the tooling data. Where a flex span passes between two rigid islands, mark both boundaries and name the layer or material that ends at each one. The rigid-to-flex boundary drawing article gives more detail on defining that geometry.

Rigid sections and flexible connections on a rigid-flex PCB.
In a common build, a polyimide flex circuit is patterned before it is combined with rigid cores. A film coverlay can then protect the exposed flex copper. The film has openings where a pad must remain accessible. A solder mask drawing for the rigid section and a coverlay drawing for the flex section control different surfaces. Label them separately and show where each ends.
Review the edge of the coverlay as well as the openings. A pad close to an opening edge can lose exposed area if the film shifts within its allowed registration. Adhesive flow can also affect the usable opening. Send the proposed pad and opening geometry together so the fabricator can review fit, registration and any coverlay overlap at the rigid boundary.
If a connector lands on the end of a flex tail, show the contact side, coverlay opening and any stiffener on the same detail. The coverlay drawing controls which copper remains accessible, while the stiffener contributes to the finished mating thickness. Check both before the artwork and tooling are released.

Multiple flexible circuits arranged in a panel.
The exact order depends on the design. Altium's rigid-flex manufacturing example documents a flex circuit embedded between rigid sections and then drilled and plated as part of a combined build. Use the fabricator's proposed sequence when a blind connection, a stiffener or a special window changes the order of operations.

Rigid-flex PCB units in a production panel.
Review the exposed flex area against the drawing. Record the rigid-edge location, the coverlay opening and the accessible area on the pads. Ask how the manufacturer checks for residual rigid material, unintended adhesive on exposed features and damage left by routing or removal. Agree which locations are visually inspected and which, if any, require a section or other evidence.
For a first-article review, identify the window corners and pad openings that matter most to assembly. Ask the inspector to report the same named features and datum the drawing uses. A photo of the whole panel can show that the flex was exposed, while a dimensioned close-up can document whether a particular opening or edge is in the intended location.
Specify electrical test against the released netlist and agree how the results will be reported. Continuity at test time and durability during repeated movement are separate requirements. If the board must operate through repeated flexing, define that application and its test conditions before finalizing the stack and inspection plan.
If electrical failures appear after profiling, preserve the panel position and inspection photos so engineering can compare the failure site with the release window, tooling and drill data.
Submit the zone map, regional stack tables, flex and coverlay outlines, metal layers, drill spans and final outline under one revision. State when a change to the bonding material, coverlay or window geometry needs written approval. Send that package for a rigid-flex manufacturing review before releasing tooling.
March/24/2026HDI Microvia Cracking | Failure Analysis Steps
December/06/2025What Are The HDI Board Risks for Radar Modules
June/24/2026High-current Heavy Copper PCB
September/28/2026PCB Annular Ring Breakout: Causes, Layer Inspection, and DFM Checks
November/12/2026PCB Assembly DFM: Practical Rules to Reduce Defects